以下是实施了与本公司主系统连接确认的机器一览。连接确认是依据本公司集成中心、项目及展⽰会等的结果。并非是保证各机器的动作。
HART通讯机器
FOUNDATION现场总线机器
现场总线机器
HART通讯机器
Vendor | Model Name | Device Category | Device Type | Device Revision | DD Revision | IFO | DTM |
---|---|---|---|---|---|---|---|
ABB | TTF300 | Temperature | 1a0b | 2 | *2 | ![]() |
|
Azbil Corporation | AVP302 | Valve Positioner | 0003 | 2 | 4 | ![]() |
![]() |
Azbil Corporation | AVP302V2 | Valve Positioner | 0014 | 1 | 2 | ![]() |
![]() |
Azbil Corporation | AVP700 | Valve Positioner | 360f | 1 | 3 | ![]() |
![]() |
Azbil Corporation | ST3000 | Pressure | 0002 | 2 | 2 | ![]() |
![]() |
Azbil Corporation | PTG | Pressure | 0005 | 1 | 2 | ![]() |
![]() |
Azbil Corporation | AT9000 | Pressure | 000d | 1 | 6 | ![]() |
![]() |
Azbil Corporation | MagneW | Flow | 0001 | 1 | 2 | ||
Azbil Corporation | MagneW 4W | Flow | 000c | 1 | 2 | ![]() |
|
Azbil Corporation | MagneW 2W | Flow | 0008 | 2 | 3 | ![]() |
|
Azbil Corporation | ThermoPlus ATT | Temperature | 0004 | 1 | 3 | ![]() |
|
Azbil Corporation | ATT082 | Temperature | 3615 | 2 | 2 | ![]() |
|
Azbil Corporation | GasCVD | Analytical | 360e | 1 | 3 | ![]() |
|
Dresser Masoneilan | SVI II AP | Valve Positioner | 00ca | 2 | 2 | ![]() |
![]() |
Endress+Hauser | ProsonicM | Level | 1111 | 2 | *2 | *1 | ![]() |
Endress+Hauser | MicropirotM | Level | 111e | 5 | *2 | *1 | ![]() |
Endress+Hauser | Promass83H | Flow | 0051 | 8 | *2 | *1 | ![]() |
Endress+Hauser | Promass60 | Flow | 1139 | 2 | 2 | ![]() |
![]() |
Emerson Process Management | MicroMotion 1700 | Flow | 1f29 | 6 | *2 | ![]() |
![]() |
Emerson Process Management | MicroMotion 2700 | Flow | 1f2a | 6 | *2 | ![]() |
|
Fisher Controls | DVC6200 | Valve Positioner | 1303 | 2 | 5 | ![]() |
![]() |
Metso Automation | VG9000H | Valve Positioner | 57d9 | 1 | *2 | ![]() |
![]() |
Mettler-Toredo | M400 2-wire | Analytical | 8e7c | 1 | *2 | ![]() |
![]() |
M-System | B3HU | Temperature | 1d02 | 1 | 1 | ![]() |
|
Oval Corporation | VXF1040 | Flow | 6465 | 1 | *2 | *1 | |
Rosemount | 248 Temperature | Temperature | 003b | 2 | 1 | ![]() |
![]() |
SAMSON AG | 373X-3 | Valve Positioner | 00ef | 6 | *2 | ![]() |
![]() |
TOA DKK | HBM-165H | Analytical | e095 | 1 | *2 | ![]() |
|
TOA DKK | WBM-165H | Analytical | e097 | 1 | *2 | ![]() |
|
Yokogawa Electric Corporation | EJA110 | Pressure | 0004 | 2 | *2 | ![]() |
![]() |
Yokogawa Electric Corporation | EJX110 | Pressure | 3751 | 3 | *2 | ![]() |
![]() |
*1 : 不可使用IFO的一部分的功能。
*2 : 使用DD的连接没有得到确认。
FOUNDATION现场总线机器
Vendor | Model Name | Device Category | Device Type | Device Revision | DD Revision | IFO | DTM |
---|---|---|---|---|---|---|---|
Azbil Corporation | AVP303 | Valve Positioner | 0203 | 1 | 2 | ![]() |
|
Azbil Corporation | AVP303 | Valve Positioner | 0203 | 2 | 1 | ![]() |
![]() |
Azbil Corporation | AVP304 | Valve Positioner | 1101 | 2 | 1 | ||
Azbil Corporation | AVP700 | Valve Positioner | 1701 | 1 | 3 | ![]() |
![]() |
Azbil Corporation | MGG | Flow | 0001 | 2 | 2 | ![]() |
|
Azbil Corporation | MagneW 3000 FLEX+/PLUS+ |
Flow | 1601 | 1 | 3 | ![]() |
|
Azbil Corporation | ST3000 S900 | Pressure | 0103 | 1 | 3 | ![]() |
|
Azbil Corporation | DSTJ3000 NewAce | Pressure | 1203 | 1 | 4 | ||
Azbil Corporation | AT9000 GTX | Pressure | 1501 | 1 | 1 | ![]() |
|
Azbil Corporation | ATT085 | Temperature | 1801 | 2 | 1 | ![]() |
|
Endress+Hauser | ProsonicM | Level | 1011 | 4 | 3 | ||
Emerson Process Management | 3051S | Pressure | 3051 | 23 | 7 | ||
Emerson Process Management | 3144P | Pressure | 3144 | 2 | 1 | ||
Emerson Process Management | 848T | Temperature | 0848 | 5 | 9 | ||
Emerson Process Management | 8732E | Flow | 8732 | 2 | 1 | ||
Emerson Process Management | DVC6000F | Valve Positioner | 4601 | 1 | 6 | ||
Fuji Electric | FBBS01 | Pressure | 0001 | 1 | 2 | ||
Honeywell | STG94L | Pressure | 0002 | 9 | 1 | ||
Honeywell | STT35F | Temperature | 0101 | 4 | 1 | ||
Metzo Automation | ND9000F | Valve Positioner | 2328 | 5 | 4 | ![]() |
![]() |
Smar International Co. | FY302 | Valve Positioner | 0006 | 4 | 2 | ||
Smar International Co. | LD302 | Pressure | 0001 | 4 | 2 | ||
TopWorx, Inc. | DVC | Valve Positioner | 0100 | 2 | 3 | ||
Yokogawa Electric Corporation | AXF | Flow | 000b | 1 | 2 | ||
Yokogawa Electric Corporation | DX204 | other | 1801 | 3 | 17 | ||
Yokogawa Electric Corporation | EJX | Pressure | 000c | 3 | 3 | ![]() |
|
Yokogawa Electric Corporation | PH202 | Analytical | 0830 | 3 | 1 | ||
Yokogawa Electric Corporation | YTA320 | Temperature | 0005 | 2 | 3 | ||
Yokogawa Electric Corporation | YVP | Valve Positioner | 0001 | 3 | 1 |
现场总线机器
Vendor | Category | Model Name | Description |
---|---|---|---|
MTL Instruments | Fieldbus Power Supply | MTL5995 | 1 segment, 350mA |
Fieldbus Power Supply | F102 | 1 segment, 500mA | |
Relcom | Fieldbus Power Supply | FPS-1 | 1 segment, redundant, 350mA |
Fieldbus Power Supply | F892 | 8 segments, redundant, 350mA | |
Device Coupler | FCS-MB4 FCS-MB8 FCS-MB10-SG-T |
4, 8, 10 spurs | |
Device Coupler | F253 | 8 spurs | |
Pepperl+Fuchs | Fieldbus Power Supply | HD2-FBPS-1.500 (module) + MB-FB-4 (backplane) | 4 segments, 500mA |
Fieldbus Power Supply | HCD2-FBPS-1.23.500 (module) + MBHC-FB-4R (backplane) | 4 segments, redundant, 500mA | |
Device Coupler | R2-SP-IC12 | 12 spurs | |
R. Stahl | Fieldbus Power Supply | 9412/00-310-11S (power supply) + 9419/04R-XX1 (bus-carriers) | 4 segments, redundant, 500mA |
Device Coupler | 9411/11-210-41 | 8 spurs | |
Device Coupler | 9410/34-330-60 | 12 spurs | |
Turck | Fieldbus Power Supply | DPC-49-4RMB/SY (power supply) + DPC-49-IPS1 (module racks) | 4 segments, redundant, 800mA |
Device Coupler | JBBS-49SC-M413/Ex | 4 spurs | |
Device Coupler | JRBS-40SC-4C/Ex | 4 spurs |