HOME > Products > Products and Services for Building Automation > Building Automation & Controls > Sensors > Single Loop Controller > Features
Single Loop Controller
Single Loop Controller is a digital indicating controller featuring multi-range inputs and PID control system using new algorithms "RationaLOOP PID (Ra-PID)" and "Just-FiTTER".
Models R35, R36
- Model R35 is a 48 × 96mm and Model R36 is a 96 × 96mm compact sized controller.
- Space saving design with a depth of 65mm. The mask of the front panel is also only 5mm thick.
- High accuracy of ± 0.1% FS and sampling cycle of 0.1 seconds.
- Multi-range inputs are available for selection, where the input type can be freely changed among RTD, current, and voltage.
- The control method can be selected from any of the ON/OFF control and PID control using "RationaLOOP PID (Ra-PID) + Just-FiTTER".
- The heat/cool control is achieved by using two control output points and event outputs.
- The controller is applicable to the communication (3-wire RS-485) as optional.
- The control output types (relay, motor drive relay, and current) can be combined by using the control outputs 1 and 2.
- Event 3 points or 2 points (independent contact), CT input 2 points, DI 4 points, RSP inputs, and RS-485 can be combined to select.
Model R15
- Model R15 is a 48 × 48mm compact sized controller.
- Compact body with a depth of 60mm. The mask of the front panel is also only 2mm thick.
- The accuracy is ± 0.5% FS.
- The input type can be changed among the RTD group and linear group.
- The control method can be selected from any of the ON/OFF control, PID control using "RationaLOOP PID (Ra-PID) + Just-FiTTER", and self-tuning.
- The heat and cool control can be achieved by using two control output points and event outputs.
- 18 kinds of operations, such as set (SP) value selection, RUN/READY selection, and latch cancellation, etc. can be set using two external switch input points.
- The process variable (PV) value can be corrected.
- The controller is applicable to the communication (3-wire RS-485) as optional.
- Up to eight points can be registered for the parameter keys, ensuring easy operation.
- Use of "mode" key ensures easy operation, RUN/READY, AUTO/MANUAL, and LSP selections, and latch cancellation.
- Up to three event output points are provided. In addition to temperature events, such as PV, DEV, and SP, CT heater burnout/overcurrent, status events such as loop diagnosis can also be set.
Feel free to contact us for consultation or inquiries regarding these products.
Online Inquiries
Inquiry Form- Building Automation & Controls
- Sensors
- Neosensor Room Temperature/Humidity Sensor
- Ceiling-Mounted Temperature Sensor(Round Type)
- Duct Temperature/Humidity Sensor
- Durable Temperature and Humidity Sensor
- Pipe Temperature Sensor
- Radiant Temperature Sensor
- Duct CO2 Sensor
- Pressure Transmitter
- Differential Pressure Transmitter
- High Accuracy Differential Pressure Transmitter
- Neostat Room Thermostat/Room Humidistat
- Single Loop Controller
- Sensors
Related Information