Actuators/Positioners
Structural drawing | ![]() |
![]() |
![]() |
---|---|---|---|
Valve type | Multispring diaphragm motor | Multispring diaphragm motor | Spring piston cylinder |
Model No. | HA2 to HA4 | PSA1 to PSA4 | PSA6R |
Action | Direct and reverse action | Direct and reverse action | Reverse action |
Stroke | 25 to 75mm | 14.3 to 38mm | 20 to 100mm |
Manual operator | Side mounted handwheel, top mounted handwheel | Side mounted handwheel, top mounted handwheel | Side mounted handwheel |
Air supply | 140 to 390kPa {1.4 to 4.0kgf/cm²} | 140 to 390kPa {1.4 to 4.0kgf/cm²} | 260 to 500kPa {2.6 to 5kgf/cm2²} |
Detailed data sheet | No.SS2-8213-0500 | No.SS2-PSA200-0100 | No.SS2-PSA100-0100 |
Features |
|
|
|
Structural drawing | ![]() |
![]() |
![]() |
---|---|---|---|
Valve type | High power spring cylinder | Springless piston cylinder | Spring diaphragm motor |
Model No. | PSA7R | DAP | VA5 |
Action | Reverse action | Direct and reverse action | Direct and reverse action |
Stroke | 50 to 100mm | 50 to 100mm | 100mm |
Manual operator | Side mounted handwheel | Hydraulic manual handle | Side mounted handwheel, top mounted handwheel |
Air supply | 400kPa {4kgf/cm²} | 200 to 700kPa {2 to 7kgf/cm²} | 140 to 270kPa {1.4 to 2.8kgf/cm²} |
Detailed data sheet | No.SS2-PSA100-0100 | No.SS2-DAP100-0100 | No.SS2-8210-0100 |
Features |
|
|
|
Structural drawing | ![]() |
![]() |
![]() |
---|---|---|---|
Valve type | Spring piston cylinder | Springless piston cylinder | Multispring lever diaphragm motor |
Model No. | GOM83S to GOM124S | GOM64LM to 154LM | HL2 to HL4 |
Action | Direct action | Direct and reverse action | Direct and reverse action |
Stroke | 75 to 100mm | 50, 100mm | - |
Manual operator | With manual handwheel | With or without handwheel | - |
Air supply | 140kPa {1.4kgf/cm²} | 200kPa {2.0kgf/cm²} | 140 to 390kPa {1.4 to 4.0kgf/cm²} |
Detailed data sheet | No.SS2-8210-0200 | No.SS2-8210-0200 | No.SS2-8213-0510 |
Features |
|
|
|
Structural drawing | ![]() |
---|---|
Valve type | Springless piston cylinder |
Model No. | GOM44L to GOM1510L |
Action | Direct and reverse action |
Stroke | 100 to 250mm |
Manual operator | With or without handwheel |
Air supply | 200kPa {2.0kgf/cm²} |
Detailed data sheet | No.SS2-8210-0200 |
Features |
|
Picture | ![]() |
![]() |
---|---|---|
Positioner type | Pneumatic positioner | Pneumatic positioner |
Model No. | HTP | VPE |
Input signal | 20 to 100, 20 to 60, 60 to 100kPa 20 to 98kPa {0.2 to 1.0kgf/cm²} |
20 to 100, 20 to 60, 60 to 100kPa 20 to 98kPa {0.2 to 1.0kgf/cm²} |
Stroke range | 6 to 100mm | 6 to 25mm |
Air supply pressure | 140 to 390kPa {1.4 to 4.0kgf/cm²} | 140 to 390kPa {1.4 to 4.0kgf/cm²} |
Ambient temperature | -25 to +60°C | -20 to +70°C |
Detailed data sheet | No.SS2-8310-0200 | No.SS2-8310-0400 |
Features |
|
|
Picture | ![]() |
![]() |
![]() |
---|---|---|---|
Positioner type | Pneumatic positioner | Pneumatic positioner | Double action, pneumatic positioner |
Model No. | VPR | VPP08 | VPP02/03 |
Input signal | 20 to 100, 20 to 60, 60 to 100kPa 20 to 98kPa {0.2 to 1.0kgf/cm²} |
20 to 100, 20 to 60, 60 to 100kPa 20 to 98kPa {0.2 to 1.0kgf/cm²} |
20 to 100, 20 to 60, 60 to 100kPa 20 to 98kPa {0.2 to 1.0kgf/cm²} |
Stroke range | 60° | 14 to 100mm | 14 to 100mm |
Air supply pressure | 340 to 490kPa {3.5 to 5.0kgf/cm²} | 350 to 690kPa {3.6 to 7.0kgf/cm²} | 200 to 690kPa {2.0 to 7.0kgf/cm²} |
Ambient temperature | -20 to +70°C | -30 to +80°C | -30 to +80°C |
Detailed data sheet | No.SS2-8310-0500 | No.SS2-8310-0600 | No.SS2-8310-0300 |
Features |
|
|
|
Feel free to contact us for consultation or inquiries regarding these products.
Online Inquiries
Inquiry Form
- Control Valves and Actuators
- Single Seated Valves
- Cage Valves, Double Seated Valves
- Angle Valves
- Eccentric Rotary Valves, Three-way Valves
- Control Valves for Specific uses (e.g., anticorrosion, power plant applications, etc.)
- Electric Valves
- D1 Series manufactured by Azbil Saudi Limited
- Smart Valve Positioners
- Actuators/Positioners
- Auxiliary Equipments for Control Valves
- Control Valve Maintenance Support System PLUG-IN Valstaff
- Optional Selection
- Control Motor, Power Controllers, Solid State Relays
Related Information