Diagnostic Tools
![Diagnostic Tools Image](https://www.azbil.com/products/factory/support-training/lifecycle-support/control-valve-solution/img/valve-tools_main.png)
How diagnosis works
Our Valve Diagnostics Service involves collecting and accumulating various diagnostic parameters held by HART®-capable Azbil Smart Valve Positioner* diagnostic devices in the control valve maintenance support system PLUG-IN Valstaff. The service uses this control valve operating data to make diagnoses.
* Models AVP701/702/703 and AVP202/207/302/307- InnovativeField Organizer(IFO)can periodically obtain and monitor various types of measurement data held by HART-enabled field instruments.
- Valstaff is a tool that specializes in diagnosing control valves by utilizing HART-enabled Azbil Smart Valve Positioners.
- IFO can monitor various HART-enabled field instruments.
- Valstaff can also run on Yokogawa’s PRM integrated instrument management package.
![System configuration example of tools required for valve diagnosis](https://www.azbil.com/products/factory/support-training/lifecycle-support/control-valve-solution/img/valve-summary-e_tool-diagram.png)
System configuration examples
If you use an azbil DCS with HART-supported I/O
![System configuration example of a customer using an azbil DCS with HART-supported I/O](https://www.azbil.com/products/factory/support-training/lifecycle-support/control-valve-solution/img/valve-tools-e_configuration-example01.png)
If you use Yokogawa CENTUM and PRM
![System configuration example of a customer using Yokogawa CENTUM and PRM](https://www.azbil.com/products/factory/support-training/lifecycle-support/control-valve-solution/img/valve-tools-e_configuration-example02.png)
System configuration that is not DCS-specific
![System configuration example that is not DCS-specific](https://www.azbil.com/products/factory/support-training/lifecycle-support/control-valve-solution/img/valve-tools-e_configuration-example03.png)
Related products
Contact information for inquiries about the Valve Diagnostics Service
- Valve Diagnostics Service
- Diagnosis Overview
- Types of diagnosis
- Service Menu
- Dx Valve Basic Service plus
- Diagnostic Tools
- Diagnosed Cases
- Use Cases, Customers, and Results
- Avoid Sudden Equipment Shutdown
- Optimizing Maintenance Plans (to TBM + CBM)
- Faster Equipment Startup after Periodic Maintenance
- Diagnostic possibilities with the Smart Valve Positioners 700 Series
- FAQ
- Introduction of our capability for factories and plants
- Maintenance Support
- Life Cycle Support
- Energy-Saving Program for Factories and Plants
- Equipment Diagnosis Support for Factories and Plants
- Advanced Automation Company Training Center
Related Information